DeltaCom DeltaCom

The Delta Com S is a modern and aesthetic electronic comparator, designed for accurate electronic measurement and inspection of specific dimensional tolerances, Max. Min & Range The unique 'Program' function provides for convenient pre-setting of values, tolerance limits and calibration. These functions are carried out by the software through one-key operations. All values and results are displayed on 2 lines (each 16 Characters) of Alphanumeric Back Light Display. LED Indicators for 'within tolerance', 'rework', 'reject' for easy visual understanding. All buttons are of the soft-touch type to facilitate ease of operation.

Features


-

  Two probe input : A, B, A/2, B/2, and Combinations

-

  Calibration and Zero setting in one key operation

-

  32 Character Back-lit Alphanumeric display

-

  Measuring possible with, or without tolerance

-

  Measuring ranges of; + 5mm, + 0.5mm, + 0.05mm

-

  LED Indicators for; 'within tolerance', 'rework' & 'reject' and   Relay output of the same

-

  Three least counts; 0.001mm, 0.0001mm, 0.00001mm

-

  Analogue output

-

  Pre-set Value input available

-

  RS 485 & RS232 output in ASCII format for computer or   gauge management

-

  True inch / metric conversion

-

  Polarity Selector for internal or external measurements

-

  Set Configuration automatically memorised at switch off

-

  Tolerance can be set for invidual probe

-

  Max Min & Range

 

 

 


Details of Operation


-

 PGM: To enter the Program Mode to set measuring range,  Preset values and Tolerance values, using selection keys,  Pressing PGM again will exit Program Mode

-

 A: To select Probe A for calibration

-

 CAL/MODE: To toggle between calibration mode, program  mode, and normal operating mode. In CAL mode, it scrolls from  AM to AM+P to TOLE to TOLI to AM

-

 B: To select Probe B for calibration

-

 UNIT/ENTER: To instantly switch between Metric/Inch  readings. Enter key also used to accept each step of  calibration.

-

 LED(Yellow): For quick indication that checked component  requires 'rework' when LED lights up

-

 TOL/RANGE: To establish the range of tolerance. Range key  used to key in different ranges. It scrolls from R1 to R2 to R3  to R1 each time the key is pressed.

-

 LED(Green): For quick indication that checked component is  'Ok' when LED lights up

-

 SEND/>(Right Arrow): Used to enter values. Done by  shifting digits to the right one at a time.
  Eg: 1234-2340-3400-4000-0000

-

 LED(Red): For quick indication that checked component is a  'reject' when LED lights up

-

 CLR/^(Up Arrow): To enter values. Done by incrementing  digits by 1 each time the key is pressed.
  Eg: 1238-1239-1230-1231

-

 SCREEN: 2 lines of 16 characters each, alpha numeric LCD  display, with backlight for easy viewing in all inspection  conditions

-

 MAX: Maximum of the probe measurement will be stored

-

 Min: Minimum of the probe measurement will be stored

-

 Range: Difference of Max and Min is total Range of  Measurement